C30 Portable Patient Monitor
Part #: c30
Category: Patient Monitoring
Sub-Category: Patient Monitors
Description
- Specifications Patient: adult, pediatric, neonate Display: 4.3 "color TFT touch screen Resolution: 16:9 2 curves on screen Sweep speed: 12.5mm / s, 25mm / s, 50mm / s Indicators: • Battery indicator light • Dual indicator alarm light QRS beep and alarm sound Key sound AC input socket MDR Trend: 48 hours Alarm: user adjustable high and low limits Connection to the monitoring center DVI connection Breathing Impedance method Rate: • Adult 0-1OOrpm • Neonatal 0-150 rpm • Resolution: ± 1 rpm Apnea alarm: 10s-40s Audible and visual alarm Sweep speed: 12.5.25mm/s Gain selection: x0.25, x0.5, x1, x2 ECG Cable: 12-lead CardioTecTM, 3 or 5 snaps (selectable) 12 leads: I, Il, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, -V6 5 wire: RA, LA, RL, LL, V or R, L, N, F, C, 3 wire: RA, LA, LL or R, L, F Lead Selection: 12 leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6 5 wire: I, Il, IIl, aVR, aVL, aVF, V 3 wire: I, Il, III Gain selection: x0.25, x0.5, x1, x2, auto Adult: 15-300 1 / min Pediatric / neonate: 15-350 1 / min Accuracy: ± 1% or ± 1 1 / min (whichever is greater) Resolution: 1 1 / min ECG bandwidth: MON: 0.5-55Hz DIA: 0.05-150 Hz OPE: 1-20Hz ST segment detection: ± 2.0mV (automatic) Arrhythmia Analysis Pacemaker pulse detection Temperature 2 channels Standard sensor: Cutaneous Measurement range: 0-50 ° C Resolution: 0.1 ° C Accuracy: 0.1 ° C (excludes sensor error) Channel: T1, T2, TD (temperature difference) PNI Measurement method: Automatic oscillometric Working mode: manual / automatic / continuous Interval: Adjustable from 1 min to 480 min Measurement types: systolic, diastolic, mean Unit of measure: mmHg / KPa, adjustable Systolic pressure range: • Adult: 40 to 270 mmHg • Pediatric: 40 to 200mmHg • Neonate: 40 to 135 mmHg Diastolic pressure range: • Adult: 10 to 215 mmHg • Pediatric: 10 to 150mmHg • Neonate: 10 to 100 mmHg Medium pressure range: • Adult: 20 to 235 mmHg • Pediatric: 20 to 165mmHg • Neonate: 20 to 110 mmHg Overpressure Protection: Hardware and Software • Accuracy: less than ± 5mmHg • Resolution: 1mmHg Sp02 Comen Range: 1-100% Resolution: 1% Accuracy: • ± 2% (70-100%, Ped, no movement) • ± 3% (70-100%, Neo, no movement) • 0-69% unspecified Range alarm: 0-100% Pulse Frequency: • Range: 20 to 300 ppm • Resolution: 1 ppm • Accuracy: - ± 3ppm (no movement) - ± 5ppm (movement) Alarm: 20 to 300 ppm EtCO2 Sidestream CO2 (SideStream) Range: 0 to 150 mmHg, 0 to 79%, • 0 to 20 kPa (at 760 mmHg) • Accuracy: ± 2mm Hg (0-40mmHg) • ± 5% of reading (41-70 mmHg) • ± 8% of reading (71-100 mmHg) • ± 10% of reading (101-150 mmHg) Frequency: 0-120 rpm Accuracy: • ± 2rpm (0-70rpm) • ± 5 rpm (> 70 rpm) Response time: <240 ms (10% to 90%) Delay time: <2s C02 COMEN Main Flow Range: 0 to 150 mm Hg, 0 to 79%, 0 to 20 kPa (at 760 mmHg) Accuracy: ± 2mmHg (0-40mmHg) • ± 5% of reading (41-70 mmHg) • ± 8% of reading (71-100 mmHg) • ± 10% of reading (101-150 mmHg) Frequency: 0-120 rpm Accuracy: • ± 2rpm (0-70rpm) • ± 5 rpm (> 70 rpm) Delay time: <2s
QUOTE HISTORY
DELIVERY
- Products are despatched or delivered within 24 hours of quote acceptance.
RETURNS
- Gammer does not have a return policy.
- All sales are final.